Same-Duty Trial Record
Compare trial checkpoints under the same duty. Record clean-start and later readings at matched flow, temperature and viscosity, then inspect the bag and outlet samples.
Filled pressures, volumes and temperatures below are illustrative inputs, not a validated operating specification.
Clean-start checkpoint
Later checkpoint
Trial termination reason
Decision and supporting observations
Illustrative checkpoint: inlet 1.5 bar, outlet 1.2 bar, 100 L in 2 hours gives 0.3 bar differential pressure and 50 L/h average processed volume.
Capture alongside each checkpoint
- Bag code, media, ring, dimensions, batch and sample reference.
- Liquid temperature, viscosity, solids and particle characteristics.
- Outlet sample result and acceptance method.
- Seal seating, basket support and bottom-seam condition.
- Termination reason: operating limit, quality failure, planned batch change or elapsed trial.
Check gauges use the same units and reflect the upstream/downstream sides of this filter. Use the housing and approved bag specification for limits. Site isolation and depressurization procedures govern inspection.