PTFE Membrane Filter Cartridges

PTFE Filter Cartridge Solutions for Liquid & Gas

Match your PTFE filter cartridge to the liquid, gas or vent duty before choosing a micron rating. ECOFILTRONE™ is an industrial filtration supplier offering hydrophobic and hydrophilic membrane filter cartridges with engineering support for media selection, replacement matching and customized filtration requirements.

  • Five series
  • 69 mm outer diameter
  • 5–40 inches
  • Quotation replies within 24 hours

Start with your duty: Send the medium, concentration, operating temperature, flow rate and current cartridge reference. We review the membrane, complete assembly and housing connection together.

PTFE Membrane Filter Cartridges

Summary of PTFE Cartridge Supply

Send your specification for an application review.

Check My Cartridge Requirements
  • Membrane options

    Hydrophobic PTFE and hydrophilic PTFE

  • Five series

    ECBTG, ECPTG, ECPT, ECPTFE and ECP

  • Cartridge envelope

    69 mm OD; catalogue lengths 5–40 inches

  • Application review

    Liquid, process gas and tank vent duty

  • Sample support

    Free samples are available; the customer pays freight.

  • Order planning

    Trial orders are accepted. Lead time is confirmed in the quotation.

PTFE Membrane Filtration for Liquid and Gas Duty

We select filter media around the process conditions, rather than treating every PTFE membrane as interchangeable. A water-based liquid needs a wetting route, while a gas cartridge needs a clear flow basis and a gas path that stays open.

Aqueous Liquid Filtration Cartridges
PHASE // 01

Aqueous Liquid Filtration

The ECP series of products is designed for filtration of aqueous solutions and process liquids, and therefore uses a hydrophilic PTFE membrane. Review other aqueous and organic solutions for their intended filtration service, and assess the complete cartridge for chemical compatibility.

Specifications

  • Candidate ratings: 0.22 and 0.45 µm
  • Record fluid composition and required cleanliness
  • Check whether wetting-agent residues are acceptable
Solvents and Process Liquids Filter
PHASE // 02

Solvents and Process Liquids

For the chemical industries, we review hydrophobic PTFE membrane filter cartridges for filtration of compatible organic solvents and process liquids. It may be necessary to pre-wet the membrane for aqueous liquid duty; in this case, the fluid used for pre-wetting and flushing should be evaluated for compatibility, as well as residue limits.

Specifications

  • Include acids, alkalis and solvent mixtures in the review
  • Check every wetted component
  • Separate clean pressure drop from the operating limit
Process Gas and Tank Vents Membrane
PHASE // 03

Process Gas and Tank Vents

Hydrophobic PTFE membrane cartridges are candidates for air and gas filtration, including tank breathing. Condensate can block the gas path, so hot or humid vent service needs a condensate-management review as well as a membrane choice.

Specifications

  • State gas flow rates and reference conditions
  • Include humidity, steam exposure and drain arrangement
  • Review drying after wet integrity testing

PTFE Wetting Check

Although many factors affect the selection of a membrane, the basic conditions, such as phase and liquid wettability, need to be evaluated first.

Bring the uncertain conditions to our application review.

ECOFILTRONE PTFE Filter Cartridge Series

Polytetrafluoroethylene (PTFE) is the membrane material across our five series, which have distinct support constructions. PTFE’s chemical resistance is not a substitute for checking polypropylene hardware and seals against your process liquid; the catalogue configuration below is the starting point for that review.

ECBTG: Hydrophobic PTFE

We provide the ECBTG product with hydrophobic PTFE membrane media and a PP support element for review in compatible process filtration. This membrane is a candidate for filtration under compatible process conditions.

  • Removal ratings: 0.1, 0.22, 0.45, 1, 3, 5 and 10 µm
  • Maximum working temperature: 80°C
  • Indicate the required rating for the liquid or gas duty.

ECPTG: Gas and Liquid Ratings

We can provide ECPTG with hydrophobic PTFE and oxidation-resistant polypropylene. Listed ratings for this series are provided separately for liquids and gases, therefore phase differentiation for specification review is explicit.

  • Liquid rating: 0.22 µm
  • Gas rating: 0.01 µm
  • Maximum working temperature: 80°C

ECPT: Double Membrane

We supply ECPT with a double hydrophobic PTFE membrane and PP components. The 0.22 + 0.22 µm notation describes the two-layer configuration; it does not become a 0.44 µm rating.

  • Double-layer rating: 0.22 + 0.22 µm
  • Maximum working temperature: 80°C
  • Confirm the retention basis for the intended duty

ECPTFE: Higher Working Temperature

We supply ECPTFE with hydrophobic PTFE and high-temperature resistant PP hardware. Its 100°C working-temperature limit differs from the 80°C limit of the other four series.

  • Liquid rating: 0.22 µm; gas rating: 0.01 µm
  • Maximum differential pressure: 5.2 bar at 20°C; 2.4 bar at 80°C
  • Obtain the pressure limit for duty at 100°C

ECP: Hydrophilic PTFE

Hydrophilic PTFE and PP components can be provided in our ECP series for selection of aqueous liquids. Define the particles to remove when evaluating filtration performance and fluid type. Consider ratings in the product data sheet.

  • Removal ratings: 0.22 and 0.45 µm
  • Maximum working temperature: 80°C
  • Catalogue heat-treatment conditions differ from the hydrophobic series
ECBTG
ECPTG
ECPT
ECPTFE
ECP
ECBTG Series PTFE Filter Cartridge ECPTG Series PTFE Filter Cartridge ECPT Series PTFE Filter Cartridge ECPTFE Series PTFE Filter Cartridge ECP Series PTFE Filter Cartridge

Another Operating Condition

Provide us a part number, data sheet or sample details if the existing cartridge does not correspond to any of the products in our catalog. We will assess the possible alternatives and customizations based on the operating conditions and housing constraints.

  • Keep the original specification and required test basis
  • Include maximum temperature and pressure excursions
  • Identify media-contact and seal requirements

End-Cap and Seal Matching

We match a replacement to the filter housing as well as the membrane requirement. Similar cartridge length does not establish a sealing fit; interface geometry, seal material and operating chemistry must agree.

Configuration Detail

Cartridge length

Send with the Enquiry

Nominal size, overall measurement and existing datasheet

Matching Decision

Confirm seating depth and housing closure clearance

Configuration Detail

End-cap interface

Send with the Enquiry

Photographs of both ends; current connection designation

Matching Decision

Review O-ring position, flat end, fin or other locating geometry

Configuration Detail

Seal or gasket

Send with the Enquiry

Existing material, medium and concentration

Matching Decision

Check compatibility under operating and cleaning conditions

Configuration Detail

Support and end caps

Send with the Enquiry

Required contact materials and temperature exposure

Matching Decision

Check the whole assembly, not only the PTFE filter membrane

Configuration Detail

Flow direction

Send with the Enquiry

Housing drawing and inlet/outlet arrangement

Matching Decision

Confirm installation direction and any reverse-pressure event

Configuration Detail

Acceptance documents

Send with the Enquiry

Required drawing, material statement and test criteria

Matching Decision

Close the configuration details before order confirmation

PTFE Cartridge Technical Specifications

We supply a pleated filter cartridge with a PTFE membrane within the model-specific limits below. Pressure limits change with temperature: a room-temperature differential-pressure rating is not interchangeable with the hot-duty limit.

Catalogue Selection Matrix

Series Removal Rating without a Stated Phase Explicit Liquid Rating Explicit Gas Rating Maximum Working Temperature Maximum Differential Pressure
ECBTG 0.1 / 0.22 / 0.45 / 1 / 3 / 5 / 10 µm Confirm duty Confirm duty 80°C 4.0 bar at 20°C; 2.0 bar at 80°C
ECPTG — 0.22 µm 0.01 µm 80°C 4.0 bar at 20°C; 2.0 bar at 80°C
ECPT 0.22 + 0.22 µm, double membrane Confirm duty Confirm duty 80°C 4.0 bar at 20°C; 2.0 bar at 80°C
ECPTFE — 0.22 µm 0.01 µm 100°C 5.2 bar at 20°C; 2.4 bar at 80°C
ECP 0.22 / 0.45 µm Confirm duty Liquid selection only; gas rating not listed 80°C 4.0 bar at 20°C; 2.0 bar at 80°C
All five series 69 mm outer diameter, approximately 2.72 in; catalogue lengths 5–40 inches Confirm the exact length, interface and seal configuration

Steam and Heat-Treatment Conditions

Series Catalogue Method Temperature / Duration Catalogue Cycles
ECBTG Autoclave and steam-in-place 135°C / 30 minutes 30
ECPTG Steam-in-place 135°C / 30 minutes 150
ECPT Steam-in-place 135°C / 30 minutes 150
ECPTFE Steam-in-place 135°C / 30 minutes 150
ECP Autoclave and steam-in-place 125°C / 30 minutes 15

These heat-treatment conditions are separate from the maximum working temperature. A cycle count is not a substitute for validating repeated use in your process; confirm the complete assembly, procedure and acceptance criteria before sterilization.

Flow and Retention Basis

For a high flow rate, the cartridge, the fluid viscosity and the pressure limitations must be assessed. The construction of the pleat alone does not determine flow capacity.

  • Liquid flow: medium, temperature, viscosity and target throughput
  • Gas flow: gas identity, reference pressure/temperature and humidity
  • retention: state the objective, challenge and required performance.
PTFE Membrane Filter Cartridges

PTFE Filter Cartridge Pricing and Lead Time

We quote the complete cartridge package. The product offered is defined by the length, connection, and seal specification. A micron rating alone is inadequate for a comparable quote.

SPECIFICATION
Index Quote Factor Information that Closes the Scope
01
Series and membrane

Hydrophobic or hydrophilic PTFE; single or double membrane

02
Rating and duty

Liquid or gas basis, filtration objective and required flow

03
Physical configuration

Length, end caps, seals and existing housing reference

04
Quantity and delivery

Trial or repeat order, destination and required arrival date

05
Documents and packaging

Technical, material and application-specific documentation requirements

PTFE Membrane Filter Cartridges configuration details
SUPPORT

Quotation and Trial Support

  • We respond to quotation inquiries within 24 hours.
  • Free samples are available; the customer pays freight.
  • Trial orders are accepted.
  • Lead time is confirmed in the quotation.
PROCESS

Compare Cost over the Actual Duty

When assessing a process, compare the total cost of ownership. Consider the cost of the system, the energy to operate the system, and the waste generated and disposed of by the system. Add the cost of system downtime due to process changeout.

  • Consider the total cost of ownership of a process when assessing service life.
  • Track clean pressure drop and its change during service
  • Separate process changes from filter loading when determining service life.

Configuration Review and Product Documentation

We provide technical data, material documentation and applicable compliance documents according to the product and application. ECOFILTRONE™ coordinates specification verification, inspection requirements and order documentation so that the ordered cartridge, supplied documents and intended use agree. Using only a nominal micron value leaves a validation gap because it does not identify the challenge method, operating conditions or acceptance criteria.

  • Confirm series, rating, dimensions, end caps and seals
  • Check operating, cleaning and thermal exposure conditions
  • Agree the inspection scope and requested document format
  • Review sample or trial requirements with the target application
  • We coordinate technical confirmation and datasheets or drawings
  • We follow production, inspection, packaging and shipping requirements
  • We support installation and replacement compatibility
  • We review operating performance, pressure trends and troubleshooting inputs

Match the test method to the duty. A hydrophobic vent filter and a wetted liquid filter require different preparation and test conditions; temperature, test pressure and the approved method belong in the specification.[5]

  • For sterile filtration, require product- and process-specific validation
  • ASTM F838 is a bacterial-retention test method for membrane filters used in liquid filtration. It is not a test method for gases.
  • An ECPTG enquiry must distinguish 0.22 µm liquid duty from 0.01 µm gas duty
  • Always ensure test limits pertain to the process under consideration and the cartridge.
Configuration review and PTFE membrane filtration process documentation

How We Work: PTFE Duty Review and Cartridge Supply

  1. 01

    Part of our job is to identify the medium, required phase, concentration and filtration objective.

  2. 02

    Operating conditions need to be defined. Indicate temperature, flow and pressure, as well as steam exposure and any special concerns related to the service.

  3. 03

    Send photographs of the end caps and seal in conjunction with a drawing of the required dimensions to confirm compatibility with the existing housing.

  4. 04

    We evaluate the requested documents and quotation and confirm the appropriateness of the selected product series.

  5. 05

    The final sample should be evaluated to verify that it meets the required performance standards and is compatible with the client’s process.

  6. 06

    Confirm and follow the order. We coordinate inspection, packing and shipping services, and support operating performance reviews.

PTFE Membrane Filter Cartridges Duty Review and Supply

PTFE Duty Passport

Centralize your enquiry inputs on material, phase, concentration, temperature, flow, inlet and outlet pressures, filtration objective, cartridge dimensions, connection and seal, cleaning, exposure and quantity. Summarize the specification conditions.

PTFE Cartridge Gallery for Replacement Matching

Use the product views with your existing datasheet and housing drawing to identify the details we need from your current cartridge. We review both end caps and overall dimensions against the housing; a similar outer cage does not establish an interchangeable cartridge.

PTFE Selection Limits and Alternatives

Select the membrane for the separation function. Mis-selection may result in insufficient flow and exposure of support components to process conditions and chemicals beyond specification.

  • The hydrophilic PTFE membrane can be wetted directly with water. Use of hydrophobic PTFE may be inappropriate where approved pre-wetting and flushing cannot meet process requirements.

  • PTFE membrane resistance does not establish the compatibility of all P.P. end caps or elastomers. For that duty, an alternative complete cartridge system may be required.

  • Excessive load of process solids may consume the service life of the membrane. A depth or high flow cartridge may be employed for a separate particle removal task.

  • Compare PES or PVDF against the chemical compatibility, extractables and acceptance criteria for each application. Determination of pore size does not establish sterile process suitability or justify a change of membrane.

PTFE Membrane Filter Cartridges

Request a PTFE Cartridge Quote

Provide ECOFILTRONE™ with a specification and duty for the PTFE filter cartridge for evaluation. We will review your requirements and provide you a proposal for the product and services required.

Specifications & Duty Parameters

  • Medium, phase, concentration, temperature and flow

  • Rating, length, connection, seal and existing part reference

  • Quantity, destination and requested documentation

PTFE Filter Cartridge Ordering Questions

01

Should I choose hydrophobic or hydrophilic PTFE for water-based liquid?

Hydrophilic ECPs can be used for direct aqueous liquid contact. A hydrophobic ptfe membrane filter may require an approved route for pre-wetting and flushing; check the route and the compatibility of the fluid with all the process components.

A hydrophobic PTFE filter may be suitable for compatible solvent filtration. Send the solvent solution at the required concentration and temperature for review of the membrane, PP support components, end caps and seals.

No. ECPTG and ECPTFE list 0.01 µm for gas and 0.22 µm for liquid; specify the phase and request the relevant challenge method, efficiency and flow basis.

No. Sterile process suitability requires validation for the cartridge, product and operating conditions, including the relevant retention and integrity-test relationship; pore size alone does not establish it.[4]

It describes a double-membrane construction with two listed 0.22 µm layers. Do not add the values or treat the notation as an independently established gas or liquid efficiency result.

No: the maximum operating temperature of the ECPTFE membrane cartridge is 100°C. Its catalogue maximum working temperature is 100°C, while steam-in-place is listed separately at 135°C for 30 minutes.

Confirm the operating constraints and limits of the system at the specified operating temperature. ECPTFE lists 5.2 bar at 20°C and 2.4 bar at 80°C; request the applicable limit for any other temperature, including 100°C. Send the maximum allowable temperature of the system.

Yes. Water on the membrane can obstruct the gas path even when the membrane remains hydrophobic; review the vent’s humidity, condensate drainage, thermal arrangement and required breathing flow.[3]

Include part reference, datasheet, dimensional drawings and pictures of both ends, along with the specific medium, temperature, flow and inlet and outlet pressures. For seal material, mention the type. If the cartridge design is single open end, show the locating feature and O-ring position; for a double open end design, show both sealing surfaces and any housing adapters.

Include the series or intended duty, rating, length, end caps, seals, quantity, destination and document requirements. We respond to quotation inquiries within 24 hours; use the PTFE Duty Passport to assemble the technical details.

Free samples are available; the customer pays freight. Trial orders are accepted, and lead time is confirmed in the quotation.