Get in touch with ECOFILTRONE™ Company
Pleated Family Router
Answer four questions about your filtration duty and the router returns the ECOFILTRONE™ pleated series that fit, in the order we usually quote them. It only routes: the final media, rating basis and seal are confirmed against your fluid data before we quote.
Your Filtration Duty
°F? Subtract 32 and multiply by 5/9.
Optional: How Many Elements
Use your own design figure; it depends on viscosity, rating and allowable pressure drop.
Series That Fit
Enter your duty and press Route My Filtration Duty.
Quote Summary to Copy
How the Router Decides
| Series | Max temperature | Rating range used | Routed for |
|---|---|---|---|
| CE | 80 °C | 0.1–100 µm nominal | Water, nominal rating |
| ECFG | 80 °C | 0.1–50 µm absolute | Water or high-purity water, absolute rating |
| ECSG | 80 °C | 0.1–20 µm | Water with mixed particle sizes |
| ECPGA | 80 °C | Confirmed in quotation | High-purity or rinse water |
| ECBS | 80 °C | 0.45–20 µm | Water, gas or vent prefiltration |
| THF | 120 °C | 0.5–20 µm | Water in 152 mm housings |
| ECTF | 160 °C | 30 nm to 5 µm | Chemicals, solvents, hot water, gas |
| ECPTFE | 100 °C | 0.01–0.22 µm | Gas and vents, chemicals, fine liquid duty |
Temperatures below 0 °C or above 160 °C return no series; send those duties to an engineer. The element count assumes flow scales in proportion to length in 10-inch steps, which is a planning estimate, not a performance guarantee.